It is used in the areas of frost prevention, open areas, car park entrances and exits, helicopter landing areas, concrete ramps, stairs and walkways.
This heating cable is designed for easy and safe installation of open-space heaters. Accidents due to frost and snow are prevented all over the heated space. To ensure a high mechanical load capacity in open space, the eltherm engineers developed this heating cable especially robust. Suited for installation in sand/cement mixtures
Advantages:
Applications:
Electrical protection
Maximum heating circuit length
According to local standards and regulations.
Take into account the conductor size and max. permitted voltage drop.
A higher voltage drop can occur at start-up of heating.
Power at start-up
To determine the installed power with the electrical system designer, the nominal current of the series connected fuse or the current value at the system start-up temperature must be taken into account (e.g. 32 A for 55 m ELSR-Ramp (–10°C).
Residual current device (RCD) 30 mA required, max. 500 m heating cable per RCD.
Remark
For the use of standard control cabinets, the maximum heating circuit length of 55 m at 32 A per heating circuit must not be exceeded
| 1) Bus wire | Nickel plated copper |
| 2)Self-regulating heating element | Conductive polymer blend |
| 3)Insulation | Modified polyolefin |
| 4) Protection | Protective braid (Cu, tin plated) |
| 5) Outer jacket | TPE pressure-grouted with protective braid |
| TECHNICAL INFORMATION | |
| Outer jacket | TPE |
| Bus wire | Nickel plated copper |
| Maximum exposure temperature (power off) | 100 °C |
| Maximum exposure temperature (power on) | 80 °C |
| Nominal voltage | 230 V |
| Bending radius, min. | 50 mm |
| Installation temperature, min. | – 20 °C |
| Nominal output | Approx.50 W/m at 10 °C (110 W/m in concrete @ 5°C) |
| Dimensions approx. | 17.2 mm x 9.5 mm |
| Weight approx. (g/m) | 253 |
This heating cable is designed for easy and safe installation of open-space heaters. Accidents due to frost and snow are prevented all over the heated space. To ensure a high mechanical load capacity in open space, the eltherm engineers developed this heating cable especially robust. Suited for installation in sand/cement mixtures
Advantages:
Applications:
Electrical protection
Maximum heating circuit length
According to local standards and regulations.
Take into account the conductor size and max. permitted voltage drop.
A higher voltage drop can occur at start-up of heating.
Power at start-up
To determine the installed power with the electrical system designer, the nominal current of the series connected fuse or the current value at the system start-up temperature must be taken into account (e.g. 32 A for 55 m ELSR-Ramp (–10°C).
Residual current device (RCD) 30 mA required, max. 500 m heating cable per RCD.
Remark
For the use of standard control cabinets, the maximum heating circuit length of 55 m at 32 A per heating circuit must not be exceeded